DKM-405 Datakom Analizator Sieci
  • DKM-405 Datakom Analizator Sieci

DKM-405 Datakom Analizator Sieci

ASDKM405 DATAKOM

DKM-405 Datakom

Analizator Sieci

710 PLN
Brutto
Ilość
Sprawdź dostępność

Zapytaj o produkt

DKM-405 Datakom Analizator Sieci

DKM-405 Datakom Analizator Sieci

DKM-405 Datakom

Analizator Sieci

Prosimy wypełnić poniższe pola formularza, biuro obsługi klienta skontaktuje się z Państwem najszybciej jak to możliwe.

* Pola wymagane

Anuluj lub 

Opis

datakom logo 
DKM-405 


Analizator sieci
Network analyser with total harmonic distortion display

FEATURES:

True RMS measurements
Total harmonic distortion display
Max demand display
Configurable relay output
Energy pulse output capability
Optically isolated, configurable digital input
Active-reactive power counters
Hour counter
Voltage transformer ratio for MV applications
Front panel programming
Reduced panel depth
Wide operating temperature range
Sealed front panel (IP54)
Plug-in connection system


TECHNICAL SPECIFICATIONS:

Power Supply Input:
     170 - 275VAC,
     50 - 60Hz nominal (± 10%)
     Different supply voltages available.
Measurement Input Range:
     Voltage: 10 - 300 V AC (L-N)
                   20 - 520 V AC (L-L)
     Current: 0.2 - 5.5 A AC
     Frequency: 30 - 100 Hz
Accuracy:
     Voltage: 0.5%+1digit
     Current: 0.5%+1 digit
     Frequency: 0.5%+1 digit
     Power(kW,kVAr): 1.0%+2digit
     Power factor: 2.0%+2digit
Measurement Range:
     CT range: 5/5A to 5000/5A
     VT range: 0.1/1 to 200.0/1
     kW range: 0.1 kW to 6.5MW
Power Consumption: < 4 W
Voltage burden: < 0.1VA per phase
Current burden: < 1VA per phase
Relay Output: 5A @ 250V AC
Digital Input:
     Active level: 5 to 30V-DC or AC
     Min pulse: 250ms.
     Isolation: 1000V AC, 1 minute
Operating Temperature: -20°C to +80°C (-4°F to +176°F).
Maximum humidity: 95% non-condensing.
Degree of Protection: IP 54 (Front Panel), IP 30 (Back panel)
Enclosure: Non-flammable, ROHS compliant
Installation: Flush mounting with rear brackets
Dimensions: 102x102x53mm (WxHxD)
Panel Cutout: 92x92mm
Weight: 200 gr
EU Directives:
     2006/95/EC (LVD)
     2004/108/EC (EMC)
Norms of reference:
     EN 61010 (safety)
     EN 61326 (EMC)