Indeks: ASTU510AMMHARSEN
TU510A-MM Harsen Sterownik Agregatu TU510A
TU510A-MM Harsen Moduł sterujący silnika agregatu TU510A
DKG-114-J Datakom
Sterownik Agregatu Prądotwórczego
DKG-114-J
DKG-114-J to sterownik agregatu prądotwórczego zaprojektowany do zdalnego lub manualnego rozruchu / zatrzymania pracy silnika. Protokół J1939 CANBUS.
FEATURES:
Both manual and remote starting and stopping
ECU control and monitoring via J1939 CANBUS
Zero power consumption at rest
Various engine brands and models supported
Automatic shutdown on fault condition
Built in alarms and warnings LED displays
Survives cranking dropouts
Sealed front panel
Plug-in connection system for easy replacement
Low cost
Small dimensions
Standard panel dimensions, (72x72mm)
INPUTS AND OUTPUTS:
FUEL: Fuel solenoid control.(10 A @28V-DC)
START: Engine starter solenoid control. (10 A @28V-DC)
ALARM: Positive output relay activated by any alarm condition. (10 A @28V-DC)
DC SUPPLY: 12 or 24 volts DC, (+) and (-) terminals.
REMOTE START: If the battery positive voltage is applied to this input the genset will start. If the positive voltage is removed, it will stop.
CHARGE: This terminal will be connected to the charge alternator D+ terminal. It will supply the
excitation current.
J1939-H / J1939-L: CANBUS connection terminals. The 120 ohms termination resistor is
inside the unit. It may be removed by jumper control.
TECHNICAL SPECIFICATIONS:
DC Supply Range: 9.0 to 30.0 V-DC
Cranking dropouts: survives 0 V for 100ms.
Typical Standby Current: 0 mA-DC in OFF mode.
Maximum Operating Current: 250 mA-DC (Relay outputs open)
DC Relay Outputs: 10 A / 28V
Charge excitation current: 150mA-min
Number of starts: 3
Start duration: 8 sec.
Wait between starts: 10 sec.
Alarm duration: 1 minute.
Protection delay: 8 sec.
Operating temp.: -20°C (-4°F) to 70 °C (158°F).
Storage temp.: -40°C (-40°F) to 80 °C (176°F).
Dimensions: 72 x 72 x 43 mm (WxHxD)
Humidity: max 95% (non-condensing)
Panel Cut-out Dimensions: 69 x 69 mm minimum.
Weight: 180 g (approx.)
Case Material: High Temp. ABS (UL94-V0, 100°C)
IP Protection: front panel:IP65, rear: IP30
Conformity: (EU directives)
-2006/95/EC (low voltage)
-2004/108/EC (electro-magnetic compatibility)
Norms of reference:
EN 61010 (safety requirements)
EN 61326 (EMC requirements)
Indeks: ASTU510AMMHARSEN
TU510A-MM Harsen Moduł sterujący silnika agregatu TU510A
Indeks: ASRGK800RDSALOVATO
RGK800RDSA panel do sterownika RGK800SA Lovato Zdalny panel do RGK 800SA, 12/24VDC, stopień ochrony IP65
Indeks: ASIM210G2COMAP
Marka: ComAp
IM 210 G2 InteliMains 210 G2 Sterownik Agregatu ComAp IM4210XXBAA Moduł sterujący silnika agregatu
Indeks: ASIL4AMF8COMAP
Marka: ComAp
InteliLite 4 AMF8 ComAp Sterownik IL4AMF8XBAA
Indeks: ASINTELIVISION8COMAP
Marka: ComAp
InteliVision 8 ComAp Odłączany moduł wyświetlacza
Indeks: ASIM1010COMAP
Marka: ComAp
InteliMains 1010 ComAp Sterownik IM31010XBBB Zaawansowany kontroler nadzoru sieciowego i zabezpieczeń dla wymagających aplikacji
Indeks: ASDKG153 DATAKOM
Marka: Datakom
DKG-153 Datakom Panel Kontrolny Agregatu Ze Stacyjką
Indeks: ASDKG727DATAKOM
Marka: Datakom
DKG-727 Datakom Sterownik Agregatu Prądotwórczego
DKG-114-J Datakom
Sterownik Agregatu Prądotwórczego